Chemical Resistance:Strong Alkalies - Fair Weak Alkalies - Good Strong Acids - Poor Weak Acids - Good Petroleum - Poor
Physical Properties:Tensile Strength (psi) - 3500 min. Ultimate Elongation - 750% min. Hardness (Shore A) - 35 +/- 5 100% Modulus (psi) - 125 max. Specific Gravity - 0.97 max.
Ozone Resistance:
Poor
UV Resistance:
Fair
Low Temperature Flex:Brittle: -67 degrees F Flexible: 0 degrees F
Recommended Sterilization:Steam Autoclave 30 minutes @ 15 psi Ethylene Oxide
Protein in Natural Rubber:
Less than 50 micrograms/gram. Fifty ug/g is detection limit of ASTM D5712-95.
Maximum Recommended Operating Temperature:212 degrees F intermittent 158 degrees F continuous
Standard Tolerances:Inside diameter:
- +/-0.015 inch on sizes up to 3/8 inch, proportionately greater on larger sizes.
Wall Thickness:
- 1/32 inch and 3/64 inch +/- 0.007 inch
- 1/16 inch and 5/64 inch +/- 0.010 inch
- 3/32 inch and 1/8 inch +/- 0.015 inch
- Wall thickness greater than 1/8 inch are gauged on the outside diameter tolerance.
Natural Rubber Latex Tubing meets or exceeds the physical properties of Commercial Item Description A-A-50247C Type I Class 1,2, and 3, Type III, Type IV, and Type V Class 1,2, and 3 which replaced Federal Specification ZZ-T-831D. Tubing is in compliance with USP Biological Classification IV.
We support the world-wide goal to eliminate the use of ozone depleting chemicals. We do not knowingly use a Class I or class II ozone depleting chemical as identified in the U.S. Clean Air Amendments of 1990 in the manufacturing process of our natural rubber latex tubing.
Leaders in the industry since 1943 Phone: 312-829-4673 Fax: 312-850-4673 |
||